top of page

Siemens 3-Pole Ground Fault Circuit Interrupters and Sensing Devices


Power up. Stay Protected.

The first 3-pole GFCI up to 100A, designed to meet expanded electrical codes. Providing unwavering and uninterrupted personnel protection in demanding commercial applications falling under National Electrical Code (NEC) 210.8(b) - like Kitchens, Laundromats, and Car Washes.


Siemens GFCI circuit breakers are UL Listed and cUL Certified as Class A devices. The ground-fault devices do not require the load current be balanced among phases for proper operation. Residual differential current (leakage current) is considered for ground-fault detection. This means superior performance and it mitigates false tripping by comparing Current Out vs. Current In.


These circuit breakers offer the Self Test feature as required by UL 943. UL suggests GFCI devices be tested every 30 days after installation. Testing GFCIs on a monthly basis is a good idea that is sometimes forgotten. The Self Test feature enables the GFCI to automatically and continuously test itself to ensure that it is working properly. If it is detected that the device has been compromised, the device trips itself. This will help guarantee the best protection is given at all times.


Features:

  • Available in 2- and 3-pole (15-100A)

  • Rated 65kA interrupting rating

  • NEC 210.8 compliant

  • Includes Self Test as required by UL943 as a needed safety feature

  • Suitable for variety of construction and commercial applications: spas, hot tubs, kitchens, bathrooms, etc.

  • Resists false tripping (shielded to prevent RF interference)

  • UL and cUL listed

  • Available sidecar accessories - shunt trip, auxiliary contact, alarm switch, etc.

  • Available in panelboard mount (bolt-on) and general purpose (cable-in/cable-out) construction

  • Din rail mountable solution

  • NEMA 1 and NEMA 3R enclosures available

  • Service entrance barrier for enclosed solution

  • Class A 5mA (UL943) and 30mA (UL1043) protection




Details



  • 3-Pole breaker with 5mA Personnel (UL943) and 30mA Equipment (UL1053) protection

  • Available from 15A to 100A, 65kA @ 208/120V

  • Panel mount and Cable-in/Cable-out breakers

  • Similar mounting as existing lighting panel breakers

  • Simple LED fault indication

  • Can be mounted in branch area of lighting and distribution panel

  • Available with internal and external accessories like Shunt trip, Aux contact etc.

  • Available with NEMA 1 and NEMA 3R enclosures



Cable-in/Cable-out


  • Complete 15A to 100A solution to meet NEC210.8 requirement

  • 65kA interrupting rating

  • Available in panelboards & switchboards

  • Full suite of accessories: shunt trip, aux switch, bell alarm, etc.

  • Can be mounted in load area pf the P1 lighting panel

  • Retrofit option available for existing panel



Bolt-on



  • Complete 15A to 100A solution to meet NEC210.8 requirement

  • 65kA interrupting rating

  • Available with NEMA1 & NEMA3R enclosures

  • Full suite of accessories: shunt trip, aux switch, bell alarm, etc.

  • Can be mounted in load area of the P1 lighting panel

  • Din rail mountable for UL508 control panels\




Power-Flo Technologies is proud to partner with Siemens as their 3-pole GFCI circuit breaker sets new standards in safety and reliability for high-demand commercial spaces. Meeting NEC 210.8(b) requirements, this breaker provides robust personnel protection, superior performance, and resistance to false tripping – all while requiring no phase balancing for operation. Its Self Test feature, alongside UL and cUL certifications, ensures the highest level of continuous protection. Designed to fit seamlessly into both new installations and retrofits, Siemens' 3-pole GFCI solution offers a versatile, powerful, and smart approach to meeting today’s electrical code demands in kitchens, laundromats, car washes, and beyond.